Outdoor Unit Specifications

TypeOutdoor Unit
UnitHeat Pumps
Performance & Electrical Ratings
Capacity Cooling (Btu/h)29,000 / 28,600
Capacity Heating (Btu/h)30,600
Air Circulation (High) Cooling CFM1,942
Number of Connectable Indoor Units2 ~ 4
SEER - Cooling17.2
EER - Cooling11.2
HSPF - Heating9.3
Power Supply V, Phase, Hz230V / 208V, 1Ph, 60Hz
Running Ampere - ACooling: 11.4 / 12.6
Heating: 10.1 / 11.2"
Power Input - WCooling: 2,600 / 2,560
Heating: 2,300
Maximum Fuse Size - Amps20A
Features
ControlsMicroprocessor
Fan SpeedsAuto (Hi, Me, Lo)
CompressorDC Inverter
Refrigerant / Amount Charged at Shipment 1b.R-410A / 6.17
Refrigerant ControlElectric Expansion Valve
Operating Sound (Hi) - dB-ACooling: 53
Heating: 55
Refrigerant Tube Connections - TypeFlare
Max. Allowable Tubing Length Ft100 (per Unit) 230 (per System with additional Refrigerant)
Refrigerant Tube Diameter - Narrow Tube - inches1/4" x 4
Refrigerant Tube Diameter - Wide Tube - inches3/8" x 2 + 1/2" x 2
Dimensions & Weight
Height (inches)35-1/32"
Width (inches)35-7/16"
Depth (inches)12-19/32"
Net Weight (lbs.)181

 

Indoor Unit Specifications:

CS-MKE12NKU

TypeWall Mounted
UnitHeat Pumps
Power Source230V-208V, 1 PH, 60 Hz
Running Ampere - A0.15 / 0.17
Power Input - W35
Capacity Cooling (Btu/h)11,900
Capacity Heating (Btu/h)14,300
Moisture Removal - High - Pints/H4.26
Dimensions & Weight
Height (inches)11"-7/32"
Width (inches)32"-15/32"
Depth (inches)7"-7/16"
Net Weight (lbs.)19.8
Air Circulation (H.M.L) Cooling CFM282 / 257 / 212
Air Circulation (H.M.L) Heating CFM294 / 271 / 218
Operating Sound (H/L) Cooling - dB-A36 / 33 / 29 / 25
Operating Sound (H/L) Heating - dB-A34 / 31 / 29 / 25
Refrigerant Tube Diameter - Narrow Tube - inches1/4"
Refrigerant Tube Diameter - Wide Tube - inches3/8"
Elevation Difference - Outdoor Above - ftMax. 50*
* This is maximum elevation difference when the indoor unit is located above the outdoor unit.
Elevation Difference - Outdoor Below - ftMax. 50*
* This is maximum elevation difference when the indoor unit is located above the outdoor unit.

CS-MKE24NKU

TypeWall Mounted
UnitHeat Pumps
Power Source230V-208V, 1 PH, 60 Hz
Running Ampere - A0.20 / 0.22
Power Input - W45
Capacity Cooling (Btu/h)24,200
Capacity Heating (Btu/h)29,000
Moisture Removal - High - Pints/H4.89
Dimensions & Weight
Height (inches)11"-23/32"
Width (inches)41"-15/16"
Depth (inches)8"-19/32"
Net Weight (lbs.)26.5
Air Circulation (H.M.L) Cooling CFM541 / 500 / 435
Air Circulation (H.M.L) Heating CFM541 / 500 / 435
Operating Sound (H/L) Cooling - dB-A44 / 41 / 38 / 30
Operating Sound (H/L) Heating - dB-A43 / 40 / 37 / 30
Refrigerant Tube Diameter - Narrow Tube - inches1/4"
Refrigerant Tube Diameter - Wide Tube - inches5/8"
Elevation Difference - Outdoor Above - ftMax. 50*
* This is maximum elevation difference when the indoor unit is located above the outdoor unit."
Elevation Difference - Outdoor Below - ftMax. 50*
* This is maximum elevation difference when the indoor unit is located above the outdoor unit."